20
(3) DC APPLICATION
The DC terminal is used only for charging
12 volt batteries. It provides up to 12V-
8.3A (100W) of maximum power.
CONNECTION OF CABLE :
Connect positive (red) terminal on
generator to positive (+) terminal on
battery.
Connect negative (black) terminal on
generator to negative (
-
) terminal on
battery.
Both AC and DC output can be used
at the same time if the total output is
within rated output of the generator.
RED
(+)
BLACK
(
-
)
(+)
(
-
)
SAFETY PRECAUTIONS WHILE CHARGING
An explosive hydrogen gas is discharged through vent holes in the battery dur-
ing the charging process. Do not allow spark or open flame around the genera-
tor or battery during the charging process.
Electrolyte fluid can burn eyes and clothing. Be extremely careful to avoid con-
tact. If injured, wash the affected area immediately with large quantities of
water and consult a doctor for treatment.
When charging a large capacity battery or totally discharged battery, excessive
current may force the DC breaker to turn off.
In such cases, use a battery charger to charge a large battery with AC output.
Battery defects may cause the DC breaker to turn off.
Check the battery before replacing the DC breaker.