Page 1 - GENERATOR

ISSUE EMD-GU2016PRINTED IN JAPANNovember 2004 CE-SKMakita Corporation3-11-8, Sumiyoshi-choAnjo, Aichi 446-8502 Japan3ZZ9020166GENERATORINSTRUCTIONS FO

Page 2 - AIR INDEX

CONTENTS1. SAFETY PRECAUTIONS・・・・・・・・・・・・・・・・・・・・・・12. SPECIFICATIONS・・・・・・・・・・・・・・・・・・・・・・・・・・43. COMPONENTS・・・・・・・・・・・・・・・・・・・・・・・・・・・54. PRE-OPERAT

Page 3

1. SAFETY PRECAUTIONS−1−Do not operate the generator near gasoline or gaseous fuel because of thepotential danger of explosion or fire.Do not fill the

Page 4

−2−Pay attention to the wiring or extension cords from the generator to the con-nected device.If the wire is under the generator or in contact with a

Page 5

−3−It is absolutely essential that you know the safe and proper use of the powertool or appliance that you intend to use. All operators must read, und

Page 6 - California Only

Specifications are subject to change without notice.*: Electric starter is available as option2. SPECIFICATIONS−4−MODEL G2800R G4100R, G4101R G6100R,

Page 7

3. COMPONENTS−5−VFUEL GAUGEPILOT LAMPSPARK PLUGOIL DRAIN PLUG OILGAUGE (OIL FILLER)KEY SWITCH(Electric starter type)CHOKE KNOBAIR CLEANERRECOIL STARTE

Page 8

UPPER LEVELLOWERLEVELOIL FILLER NECKOIL GAUGE(OIL FILLER)UPPER LEVELLOWER LEVEL4. PRE-OPERATION CHECKS−6−CHECK ENGINE OIL.Before checking or refilling

Page 9 - FOREWORD

Check fuel level at fuel level gauge. If fuel level is low, refill with unlead-ed automotive gasoline.This engine is certified to operateon automotiv

Page 10 - CONTENTS

CHECKING COMPONENT PARTSCheck following items before starting engine: Fuel leakage from fuel hose, etc. Bolts and nuts for looseness. Components for d

Page 11 - 1. SAFETY PRECAUTIONS

−9−BATTERY INSTALLTION (Electric starter model)Recommended Battery: A capacity of 12V-24AH or larger.Death, personal injury and/or property damage may

Page 12

The engine exhaust from this product containschemicals known to the State of California tocause cancer, birth defects or other reproductiveharm.WARNIN

Page 13

−10−GROUNDING THE GENERATOR To ground the generator to the earth,connect the grounding lug of the gen-erator to the grounding spike driveninto the ear

Page 14 - 2. SPECIFICATIONS

(a) Turn the engine switch to the position"ON". (Recoil starter model only)(b) Turn the no-fuse breaker to the "OFF"position.(c) O

Page 15 - 3. COMPONENTS

−12−(f)[Electric starter model]Insert the key into the key switch andturn it clockwise to the "RUN" positionto start the engine.Then turn th

Page 16 - 4. PRE-OPERATION CHECKS

−13−USING ELECTRIC POWER Make sure that the appliance is switched OFF before connecting it tothe generator. Do not move the generator while it is runn

Page 17 - CHECK ENGINE FUEL

−14−(G4101R / G4100R)AC MAX 30A30A125V20A125V20ARESETTESTAC MAX 20AAC MAX 20AAC MAX 20A120V/240V120VFULL POWER SWITCHIDLE CONTROLG4100RBattery chargeo

Page 18 - CHECK GENERATOR SURROUNDINGS

−15−(1) AC APPLICATION(a) Check the pilot lamp for proper voltage. This generator is thoroughly tested andadjusted in the factory. If the generatordoe

Page 19

−16−NOTE :When the no-fuse breaker turns off during operation, the generator is over loadedor the appliance is defective. Stop the generator immediate

Page 20 - GROUNDING THE

−17−FULL POWER SWITCHSelect the voltage using the FULLPOWER SWITCH in accordance with theelectrical appliance. Refer to TABLE 2.120V 120V 240V Change

Page 21 - 5. OPERATING PROCEDURES

−18−(2) CONNECTING TO DOMESTIC CIRCUITS (HOUSE WIRING)All Makita generators are a neutral grounded type.If a generator is to be connected to residenti

Page 22

−19−Utility high lineMeter boxGeneratorHouse circuit breakerXWYX(X)(Y)(G)(W)WYTransferswitch240V4P- Receptacle120Vappliance120Vappliance240Vappliance(

Page 23 - USING ELECTRIC POWER

FEDERAL EMISSIONS COMPONENT DEFECT WARRANTYEMISSIONS COMPONENT DEFECT WARRANTY COVERAGE - This emission warranty is applic-able in all States, except

Page 24 - (G6101R / G6100R)

−20−(3) DC APPLICATIONThe DC terminal is used only for charging12 volt batteries. It provides up to 12V-8.3A (100W) of maximum power.CONNECTION OF CAB

Page 25 - PILOT LAMP

−21−STOPPING THE GENERATOR(a) Turn off the power switch of the elec-tric equipment and unplug the cordfrom receptacle of the generator.(b) Turn the no

Page 26 - Receptacle, duplex

−22−(1) HOW TO USE IDLE CONTROL Start the engine with IDLE CONTROLSWITCH off.NOTE :Warm up the engine without a load for afew minutes. Turn IDLE CONTR

Page 27 - 120V 120V

6. WATTAGE INFORMATION−23−Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to s

Page 28 - CONNECTING BOX

−24−VOLTAGE DROP IN ELECTRIC EXTENSION CORDSWhen a long electric extension cord is used to connect an appliance or tool to thegenerator, a certain amo

Page 29

7. SPARK ARRESTER−25−SPARK ARRESTERIn a dry or wooded area, it is recommendable to use the product with a spark arrester.Some areas require the use of

Page 30

8. MAINTENANCE SCHEDULE−26−DAILY INSPECTIONBefore running the generator, check the following service items:Excessive vibration,noiseClean air cleaner

Page 31 - OIL SENSOR

−27−*NOTE: 1. Initial oil change should be performed after first twenty (20) hours ofoperation. Thereafter change oil every hundred (100) hours. Befor

Page 32 - IDLE CONTROL (Except G2800R)

−28−9. "HOW-TO" MAINTENANCEENGINE OIL CHANGE Change engine oil every 100 hours.(For new engine, change oil after 20hours.)(a) Drain oil by r

Page 33 - 6. WATTAGE INFORMATION

−29−COVERINNERELEMENTOUTERELEMENT1. Urethane Foam ElementWash and clean the urethane foam with detergent. After cleaning, dry it.Clean the urethane fo

Page 34 - EXTENSION CORD CHART

*The replacement parts used for required maintenance services.*Consequential damages such as loss of time, inconvenience, loss of use of the engine or

Page 35 - 7. SPARK ARRESTER

−30−CLEANING FUEL STRAINERDirt and water in the fuel are removed bythe fuel strainer.(a) Remove the strainer cup and throwaway water and dirt.(b) Clea

Page 36 - 8. MAINTENANCE SCHEDULE

−31−10. PREPARATION FOR STORAGEThe following procedures should be followed prior to storage of your generator forperiods of 6 months or longer. Drain

Page 37 - REPLACE FUEL LINES

11. TROUBLESHOOTING−32−When generator engine fails to start after several attempts, or if no electricity isavailable at the output socket, check the f

Page 38 - CLEANING AIR CLEANER

12. WIRING DIAGRAM−33−G2800RV+-REC1Field WindingDiodeSurge absorberAuxiliaryWindingforcondenserAC Winding 1AC Winding 21.25Grn1.25Brn1.25Brn0.75Y0.75Y

Page 39 - SPARK PLUG

−34−G4100RV+-120V120V120/240V120/240VREC1WWREC4GENERATOR CONTROL BOXField WindingAC Winding 2 AC Winding 1DC WindingDiodeSarge absorberAuxiliaryWindin

Page 40 - FUEL HOSE REPLACEMENT

−35−G4101REarth(Ground) terminal1.25Grn1.25R1.25OrSTB-M+MIGKey switchBatteryMagnetiecswitch14R14BlkElectricstarterV+-120V120V120/240VREC1WWREC4GENERAT

Page 41 - 10. PREPARATION FOR STORAGE

−36−G6100RV+-120V120V120/240V81953674289153674REC1REC4WWREC2GENERATOR CONTROL BOXField WindingAC Winding 2 AC Winding 1DC WindingDiodeSarge absorber2

Page 42 - 11. TROUBLESHOOTING

−37−G6101RV+-120V120V120/240V81953674289153674REC1REC4W+-REC2GENERATOR CONTROL BOXField WindingAC Winding 2 AC Winding 1DC WindingDiodeSarge absorber2

Page 43 - 12. WIRING DIAGRAM

13. OPTIONAL PARTS−38−"HOW TO" INSTALL BATTERYG28R-G61R 米国取説GU2016 05.1.26 11:15 AM ページ38

Page 44 - GENERATOR CONTROL BOX

ISSUE EMD-GU2016PRINTED IN JAPANNovember 2004 CE-SKMakita Corporation3-11-8, Sumiyoshi-choAnjo, Aichi 446-8502 Japan3ZZ9020166GENERATORINSTRUCTIONS FO

Page 45

CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT(This warranty does not apply in any other state.)YOUR WARRANTY RIGHTS AND OBLIGATIONSThe California Air

Page 46

LIMITED WARRANTYon Emission Control Systems-California Only -MAKITA , a distributor of small off-road equipment in the U.S., warrants to the owner of

Page 47

If it is determined by an authorized warranty station that other engine components have beendamaged due to the failure of a warranted emission-related

Page 48 - 13. OPTIONAL PARTS

REPAIR AND REPLACEMENT OF EMISSION-RELATED PARTSIt is recommended that only engine replacement parts which have been authorized andapproved by MAKITA

Page 49

Thank you for purchasing a Makita generator.This manual covers operation and maintenance of the Makita generators.All information in this publication

Comments to this Manuals