TROUBLESHOOTING GUIDE
17
OWNERS MANUAL
MAKITA - MAC700 / MAC2400 / MAC5200
PROBLEM CAUSE CORRECTION
Motor will not run. (con’t)
Regulator knob has continuous
air leak. Regulator will not shut
off at air outlet.
Check valve is stuck open.
Loose electrical connections.
Possible defective capacitor.
Paint spray on internal motor
parts.
Possible defective motor.
Fuse Blown, circuit breaker
tripped.
Pressure unloader valve on
pressure switch has not
unloaded head pressure.
Dirty or damaged regulator
internal parts.
Remove and clean, or replace.
Check wiring connection inside
pressure switch and terminal
box area.
Return to an Authorized
Warranty Service Center for
inspection or replacement if
necessary.
Have checked at an
Authorized Warranty Service
Center. Do not operate the
compressor in the paint spray
area. See flammable vapor
warning.
Have checked at an
Authorized Warranty Service
Center.
Check fuse box for blown fuse
and replace. If necessary,
reset circuit breaker. Do not
use a fuse or circuit breaker
with higher rating than
specified for your particular
branch circuit.
Check for low voltage
conditions and/or proper
extension cord.
Disconnect the other electrical
appliances from circuit or
operate the compressor on its
own branch circuit.
Bleed the line by pushing the
lever on the pressure switch to
the "off" position; if the valve
does not open, replace it.
Replace regulator.