Makita MAC5501G Use and Care Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
FILLING THE COMPRESSOR WITH OIL
BEFORE OPERATING THE AIR COMPRESSOR 1) Remove the oil filler plug
PLEASE CHECK THE FOLLOWING CAREFULLY: 2) Slowly pour the proper oil into the pump
1) Check to see that nuts and bolts are all crankcase
snug. 3) Always keep oil level in the middle of the
2) Check if the quantity and quality of oil sight glass
is correct.
3) If the intake filters are dirty, they should OIL CHANGES
be replaced or cleaned.
INITIAL OIL CHANGE DUE AT 25 HOURS
COMPRESSOR LUBRICATION Change oil every 300 hours or 3 months -
Always check the oil level and quality before whichever comes first.
start-up. DO NOT ADD OR CHANGE OIL
WHILE THE UNIT IS RUNNING. Use only 1) Remove the oil drain plug. Allow oil to
recommended non-detergent oil. drain completely.
2) Replace the oil drain plug.
RECOMMENDED OIL 3) Refill with the recommended oil to the
Compressor oil: #EAOIL10 (1 Liter) proper level.
Compressor oil:
#EAOIL40 (4 Liters)
*Compressor originally filled with SAE 30W ENGINE LUBRICATION
oil Check engine Owner's manual for lubrication
and maintenance requirements.
Compressor oil is a non-detergent mineral
oil formulated with additives to help MAINTENANCE
minimize carbon build-up, increase ring life, Before doing any maintenance or adjust-
and reduce oil consumption, for use at ments to your air compressor, the following
ambient temperatures of 32º F - 86º F
safety precautions should be taken:
(0º to 30º C)
1) Turn off engine. Wait until engine is
completely stopped.
OTHER APPROVED OILS 2) Drain air receiver and air lines of air
Regular mineral oils can also be used in pressure.
Makita compressors. Always use a non-
detergent oil with the following
specifications:
AMBIENT TEMPERATURES AT
SAE ISO
POINT OF OPERATION
VISCOSITY VISCOSITY
-16º C TO 0°C (3.2°F - 32°F)
SAE 10W ISO 32
1º C TO 26°C (33.8°F - 78.8°F)
SAE 20W ISO 68
ABOVE 27 °C (80.6°F)
SAE 30W ISO 100
Page 12
OPERATING PROCEDURES
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 43 44

Comments to this Manuals