18
Utility high line
Meter box
Generator
House circuit breaker
XWY
X
(
X
)(
Y
)
(
G
)
(
W
)
WY
Transfer
switch
240V
4P- Receptacle
120V
appliance
120V
appliance
240V
appliance
(c) Operating the generator.
Set the full power switch to 120V/ 240V side.
Turn the house AC breaker off before starting the generator.
Start the generator and warm it up.
Turn the house AC breaker on.
Do not start the generator with electrical appliance (s) connected and
with their switches on.
Otherwise the appliance (s) may be damaged by the surge voltage at
starting.
CAUTION