Makita Pump EW400R Instruction Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
a.
"HOW
TOWAINTENANCE
INSPECTING THE SPARK PLUG
w
Clean
off
carbon deposits on the plug
electrode using a plug cleaner or wire
brush.
Check electrode gap.
Adjust it to between
0.02
and
0.03
inches.
(0.6
and 0.7")
ENGINE OIL CHANGE
Initial oil change
......
20
hours of operation
Thereafter.. .Every
50
hours of operation
:CAUTION]-
Make sure the fuel cap is tightly se-
cured to avoid spillage.
. When changing oil, stop the engine
and loosen the drain plug.
.
Tighten the drain plug before refilling.
. Refer to the recommended oil table
on page
3.
.
Always use the proper grade and
clean oil. If the engine oil is contam-
inated, there is not enough or
it
is of
poor quality, engine life will be short-
ened.
0.6-0.7mm
-&-
(0.02-0.03
in.)
CLEANING FUEL STRAINER
Check for water or contaminants in the fuel strainer.
To
remove contaminants, close the fuel cock and remove the strainer cup.
After removing contaminants and water, wash the strainer cup with kerosene.
Reinstall it securely to prevent leakage.
-
10
-
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 19 20

Comments to this Manuals