Makita MAC2200 Troubleshooting Guide Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
DESCRIPTION
OF
OPERATION
(cont’d)
Pressure Release Valve:
The pressure release valve located
on the side of the pressure switch, is designed to automatically
release compressed air from the compressor head and the
outlet tube when the air compressor reaches “cut-out” pres-
sure or is shut
off.
If the air is not released, the motor will try
to start, but will be unable to. The pressure release valve allows
the motor to restart freely. When the motor stops running, air
will be heard escaping from this valve for a few seconds. No
air should be heard leaking when the motor is running, or
continuous leaking after unit reaches cut-out pressure.
Outlet Pressure Gauge:
The outlet pressure gauge indicates
the air pressure available at the outlet side of the regulator.
This pressure is controlled by the regulator and is always less
or equal to the tank pressure. See “Operating Procedures”.
Tank Pressure Gauge:
The tank pressure gauge indicates
the reserve air pressure in the tank.
Regulator:
The air pressure coming from the air tank is
controlled by the regulator knob. Turn the knob clockwise to
increase pressure and counterclockwise to decrease pres-
sure. To avoid minor readjustment after making a change in
pressure
Switch:
The
Pressure
switch
starts
the
motor
when
the
air
tank
Pressure drops
to
the
factory
set
pressure setting, always approach the desired pressure from
a
lower
pressure. When reducing from a higher
to
a lower
“cut-in” pressure.
pressure reaches the factory set “cut-out” pressure.
It
stops
the
motor
when
the
air
tank
setting, first reduce to some pressure less than that desired,
then brincr up to the desired pressure. Depending on the air
-.
Safety Valve:
If the pressure switch does not shut off the air
compressor at its cut-out pressure setting, the safety valve will
protect against high pressure by “popping out” at its factory
set pressure (slightly higher than the pressure switch cut-out
setting).
requirements of each particu‘lar accessory, the outlet regu-
lated air pressure may have to be adjusted while you are
operating the accessory.
-
INSTALLATION
AND
BREAK-IN
Location
of
the Air Compressor
Piping (cont’d)
Locate the air compressor in a clean, dry and well ventilated
area. The air filter must be kept clear of obstructions which
could reduce air delivery of the air compressor. The air
compressor should be located at least 12” away from the wall
or other obstructions that will interfere with the flow of air. The
air compressor head and shroud are designed to allow for
proper cooling. If humidity is high, an air filter can be installed
on the air outlet adapter to remove excessive moisture.
Follow
the instructions packaged with the air filter for proper installa-
tion.
Lubrication and
Oil
This unit needs no lubrication or oiling.
Extension
Cords
PROCEDURES
-
If
a pipe line is necessary, use pipe that is the same size as the
air tank outlet. Piping that is too small will restrict the flow of
air. If piping is over
100
feet long, use the next larger size. Bury
underground lines below the frost line and avoid pockets
where condensation can gather and freeze. Apply pressure
before underground lines are covered to make sure all pipe
joints are free of leaks.
GROUNDING INSTRUCTION
RISK
OF
ELECTRICAL SHOCK! In the event of
a short circuit, grounding reduces the risk of
shock by providing an escape wire for the
electric current. This air compressor must be
properly grounded.
To avoid voltage drop, power
loss,
and overheating of the
motor, use extra air hose instead of an extension cord.
Low voltage can cause damage to the motor.
If an extension cord
must
be used:
use only a 3-wire extension cord that has a 3-blade ground-
ing plug and a 3-slot receptacle that will accept the plug on
the air compressor.
make sure the extension cord is in good condition.
the extension cord should be no longer than
50
feet.
the minimum wire size is 12 gauge (AWG). (Wire size
increases as gauge number decreases. 10 AWG and
8
AWG
may also be used.
DO
NOT
USE
14 AWG or
16
AWG.)
The air compressor is equipped with a cord having a grounding
wire with an appropriate grounding plug. The plug must be
used with an outlet that has been installed and grounded in
accordance with all local codes and ordinances. The outlet
must have the same configuration as the plug. See illustration.
DO
NOT USE AN ADAPTER.
Inspect the plug and cord before each use.
Do
not use
if
there are signs
of
damage.
Piping
IMPROPER GROUNDING CAN RESULT IN
ELECTRICAL SHOCK.
Plastic or
PVC
pipe
is
not designed for use with
compressed air. Regardless
of
its
indicated
pressure rating, plastic pipe can burst from air
pressure. Use only metal pipe for air distribu-
Do
not modify the plug that has been provided. If it does
not
fit
the available outlet, the correct outlet should be
installed by a qualified electrician.
..
tion lines.
continued
c
6
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 47 48

Comments to this Manuals

No comments