Makita GA7050 Instruction Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
4
ENGLISH (Original instructions)
Explanation of general view
1-1. Shaft lock
2-1. Switch trigger
2-2. Lock lever
3-1. Indication lamp
5-1. Wheel guard
5-2. Screw
5-3. Bearing box
6-1. Wheel guard
6-2. Bearing box
6-3. Nut
6-4. Lever
7-1. Nut
7-2. Lever
8-1. Lock nut
8-2. Depressed center wheel
8-3. Inner flange
8-4. Super flange
9-1. Lock nut
9-2. Depressed center wheel
9-3. Inner flange
10-1. Lock nut wrench
10-2. Shaft lock
11-1. Lock nut
11-2. Abrasive disc
11-3. Rubber pad
12-1. Ezynut
12-2. Abrasive wheel/Multi-disc
12-3. Inner flange
12-4. Spindle
13-1. Shaft lock
14-1. Arrow
14-2. Notch
17-1. Wire cup brush
18-1. Wire wheel brush
19-1. Lock nut
19-2. Abrasive cut-off wheel/diamond
wheel
19-3. Inner flange
19-4. Wheel guard for abrasive cut-off
wheel/diamond wheel
20-1. Lock nut
20-2. Outer flange 78
20-3. Abrasive cut-off wheel/diamond
wheel
20-4. Inner flange 78
20-5. Wheel guard for abrasive cut-off
wheel/diamond wheel
21-1. Exhaust vent
21-2. Inhalation vent
22-1. Commutator
22-2. Insulating tip
22-3. Carbon brush
23-1. Brush holder cap
23-2. Screwdriver
SPECIFICATIONS
Model GA7050 GA7050R GA9050 GA9050R
Depressed center wheel diameter 180 mm 180 mm 230 mm 230 mm
Spindle thread M14 M14 M14 M14
No load speed (n
0
)/Rated speed (n) 8,500(min
-1
)8,500(min
-1
)6,600(min
-1
)6,600(min
-1
)
Overall length 432 mm 455 mm 432 mm 455 mm
Net weight 4.5 kg 4.6 kg 4.7 kg 4.8 kg
Safety class /II
• Due to our continuing programme of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
ENE048-1
Intended use
The tool is intended for grinding, sanding and cutting of
metal and stone materials without the use of water.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and can
only be operated on single-phase AC supply. They are
double-insulated and can, therefore, also be used from
sockets without earth wire.
For Model GA7050, GA9050
ENF100-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.22 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected with
a fuse or protective circuit breaker having slow tripping
characteristics.
ENG905-1
Noise
The typical A-weighted noise level determined according
to EN60745:
Sound pressure level (L
pA
) : 94 dB(A)
Sound power level (L
WA
) : 105 dB(A)
Uncertainty (K) : 3 dB(A)
Wear ear protection
ENG900-1
Vibration
The vibration total value (tri-axial vector sum) determined
according to EN60745:
Page view 3
1 2 3 4 5 6 7 8 9 ... 79 80

Comments to this Manuals

No comments