Makita EST-48 User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
17
Figure 47
FINISH TO YOUR TASTE
There are a wide variety of finished looks for
these fireplaces, from formal wall decor with
elaborate mantels to rustic wood paneling or
warm brick facings.
Only noncombustible materials like stone, tile,
brick, etc., may overlap the black front facing.
Do not extend these materials beyond the black
facing and into the firebox area. Be sure not to
interfere with the installation and operation of
glass doors or block the upper or lower grilles.
Seal all joints between the black facing and wall
surrounds to prevent air intrusion. Use non-
combustible caulking material only to seal the
black metal facing to the surround material on
the finished wall.
Outside Combustion Air Kits
(with duct) 81L87 FOAK
(without duct) 81L88 FOAK-LD
Combination
Offset/Return Elbow 63L35 FTF13-OR15
Firestop Spacer (30°) 63L37 F10FS30-2
Offset/ Return
Package (30°) 63L24 FTF13-ES30
INSTALLATION COMPONENTS
The following items are available for use in the
installation of this appliance.
The sum of all R values is:
.70 + .10 + .068 + .5825 = 1.4505
This would be an acceptable combination of
materials for the hearth extension since the
total calculated R value of all material used
exceed the required R value of 1.19.
WARNING: THE CRACK BETWEEN THE
FIREPLACE AND THE HEARTH EXTEN-
SION MUST BE SEALED WITH A NON-
COMBUSTIBLE MATERIAL.
WARNING: THE FIREPLACE MUST BE
RAISED IF THE HEIGHT OF THE HEARTH
EXTENSION EXCEEDS 8 ¹⁄₂" ABOVE THE
BOTTOM OF THE FIREPLACE (
FIGURE
46
).
Figure 46
8 ¹⁄₂" Max.
Maximum Thickness of Hearth Extension
when EST-48 is on the Floor
Combustible materials may project beyond the
sides of the fireplace opening as long as they
are kept within the shaded areas illustrated in
Figure 47
.
Chase Termination
(Square) 63L54 FTF13-CT2
Stabilizer 63L27 FTF13-S4
Locking Band 63L60 FLB
4 ³⁄₄"
3 ¹⁄₄"
18" Min.
Distance to
Unprotected Side Wall
12" Min.
Distance to
Protected Side Wall
Fireplace
¹⁄₂"
Combustible
Materials Allowed
in Shaded Areas
15°
Page view 16