ASSEMBLY INSTRUCTIONS
CAUTION : Before performing any work on the blower, always stop
the engine and pull the spark plug connectors off the
spark plug.
Always wear protective gloves!
CAUTION : Start the blower only after having assembled it com-
pletely.
1. ASSEMBLY OF BLOWER PIPES
1) Align grooves in the blower pipe with pegs on the blower
housing and slide the pipe onto housing.
2) Turn the blower pipe clockwise to lock it into place.
3) Place clamp around the opening of the blower pipe. Fas-
ten securely with bolt and nut .
2. ASSEMBLY OF VACUUM ATTACHMENT
1) Installing Vacuum pipe (nozzle)
(1) Loosen the screw and open the protector .
It is dangerous to operate the machine with the screw loosened.
The operator’s finger or clothing may be caught in the impeller, which will
result in a serious accident.
Caution : The engine will not start unless the protector is closed
completely.
(2) Align the indicated on the vacuum pipe with the “ ” indi-
cated on the blower. Then insert the vacuum pipe into the
blower.
(3) Turn the vacuum pipe until the is aligned with the “
indicated on the blower to lock the vacuum pipe.
(4) Fasten the vacuum pipe securely to the blower with screw
and bracket .
Caution : Do not perform the fastening operation in (4) above if the
blower is to be used in a country or region where the CE mark
is not applicable.
Caution : The screw do not tighten strongly too much.
Caution : The engine will not start unless the vacuum pipe is mounted
completely.
WARNING!
Always hold the mounting end of the vacuum pipe when attaching/
detaching the vacuum pipe.
2) Installing Elbow and Dust Bag
(1) Open the fastener of the dust bag.
(2) Insert the elbow into the dust bag and take it out through the
bag’s entry.
(3) Install the elbow on the blower.
(4) Place clamp around the opening of the elbow. Fasten
securely with bolt and nut .
Caution : Do not perform the fastening operation in (4) above if the
blower is to be used in a country or region where the CE mark
is not applicable.
Always mount the protector/vacuum pipe in the right way before opera-
tion. Operation without the protector/vacuum pipe is dangerous, the
impeller may catch the operator’s fingers or clothes and it can result in
serious injury.
Do not attempt to remove the screw (1) or disassemble the vacuum pipe.
Regulation requires safety distance of at least 900 mm between the
impeller and the top of the pipe.
WARNING!
When using this machine as a blower, be sure to confirm
that the screw is not loosened at each time of startup. If
the screw is loosened, retighten it.
WARNING!
Do not attempt to pick up large wood chips, metals,
glass, stones, liquids, lighted cigarettes, fire works or
the like.