ENGLISH (Original instructions)
SPECIFICATIONS
Model
HR2800/
HR2810
HR2810T HR2811F HR2811FT
Tungsten-carbide tipped bit 28 mm
Core bit 80 mm
Concrete
Diamond core bit (dry type) 80 mm
Steel 13 mm
Capacities
Wood 32 mm
No load speed (min
-1
) 0 - 1,100
Blows per minute 0 - 4,500
Overall length 314 mm 339 mm 320 mm 345 mm
Net weight 3.4 kg 3.5 kg 3.5 kg 3.6 kg
Safety class /II
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
END201-5
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
Read instruction manual.
DOUBLE INSULATION
Only for EU countries
Do not dispose of electric equipment
together with household waste
material!
In observance of European Directive
2002/96/EC on waste electric and
electronic equipment and its
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an environmentally compatible
recycling facility.
For Model HR2800
ENE042-1
Intended use
The tool is intended for hammer drilling and drilling in
brick, concrete and stone.
It is also suitable for drilling without impact in wood,
metal, ceramic and plastic.
For Model HR2810, HR2810T, HR2811F, HR2811FT
ENE043-1
Intended use
The tool is intended for hammer drilling and drilling in
brick, concrete and stone as well as for chiselling work.
It is also suitable for drilling without impact in wood,
metal, ceramic and plastic.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
ENG905-1
Noise
The typical A-weighted noise level determined
according to EN60745:
Model HR2800
Sound pressure level (L
pA
) : 89 dB(A)
Sound power level (L
WA
) : 100 dB(A)
Uncertainty (K) : 3 dB(A)
Model HR2810, HR2810T
Sound pressure level (L
pA
) : 89 dB(A)
Sound power level (L
WA
) : 100 dB(A)
Uncertainty (K) : 3 dB(A)
Model HR2811F, HR2811FT
Sound pressure level (L
pA
) : 90 dB(A)
Sound power level (L
WA
) : 101 dB(A)
Uncertainty (K) : 3 dB(A)