13
Checking and adjusting the idling speed
The cutting blades should not run when the engine is at idle.
- Idle speed should be set to 3,000 min
-1
(rpm).
- If necessary, adjust the idle screw (the cutting blades must not run when the
engine is on idle).
The cutting blades run while idling - turn the idle screw counterclockwise to
decrease the idle speed.
The engine stops while idling - turn the idle screw clockwise to increase the idle
speed.
If the cutting blades still continue to run at idle after the adjustment, consult your
nearest authorized service agent.
• The clutch should engage at 3,750 min
-1
(rpm) or higher revolution.
Check the functioning of the I-O switch, the lock-off lever and the throttle lever.
Cleaning the air cleaner
DANGER: Inammables strictly prohibited
Check and clean the air cleaner daily or every 10 operating hours.
- Turn the choke lever to the close side fully, and keep the carburetor free from
dust or dirt.
- Loosen the xing bolt.
- Pull the rear side of the air cleaner cover and move it forward to detach.
- If oil adheres to the element (sponge), squeeze it rmly.
- For heavy contamination:
1) Remove the element (sponge), immerse it in warm water or in water-diluted
neutral detergent, and dry it completely.
2) Clean the element (felt) with gasoline, and dry it completely.
- Before attaching the elements, be sure to dry it completely. Insufcient drying of
the elements may lead to difcult startup.
- Wipe out oil adhering around the air cleaner with waste cloth.
- Immediately after cleaning is nished, attach the cleaner cover and tighten it with
xing bolts. (In remounting, rst place the upper claw.)
Points in handling the air cleaner elements
- Clean the elements several times a day, if excessive dust adheres to it.
- If operation continues with the elements remaining not cleared of oil, oil in
the air cleaner may fall outside, resulting in oil contamination.
Element (Sponge)
Fixing bolt
Element (felt)
Upper claw
Page view 12