Page view 39
15
Appendix
Makita LD100P
D
GB
F
I
E
NL
P
N
FIN
DK
S
TR
CZ
SK
PL
SLO
HR
H
GR
RUS
LV
EST
LT
ROK
CN
Technical data
252
Temperature too
high
Cool down instrument
253
Temperature too
low
Warm up instrument
255
Receiver signal too
weak, measurement
time too long,
distance > 100 m
Use target plate
256
Received signal too
strong
Target too reflective
(use target plate)
257
Wrong measure-
ment, background
brightness too high
Darken target (measure
in different lighting
conditions)
260
Laser beam inter-
rupted
Repeat measurement
Error Cause Remedy
Error Hardware error Switch on/off the
device several times. If
the symbol still
appears, then your
instrument is defective.
Please call your dealer
for assistance.
Cause Remedy
Distance
measurements:
Measuring accuracy
up to 10 m
(2
σ
, standard deviation)
typically: ± 1.5 mm*
Power Range
Technology™:
Range (use target plate
from about 80m)
0.05 m to 100 m
Smallest unit displayed 0.1 mm
Distance measurement
9
Minimum/maximum
measurement, Continuous
measurement
9
Area/volume calculation of
room data
9
Addition / subtraction
9
Indirect measurement
using Pythagoras
9
Tilt measurements:
Tilt sensor:
Accuracy
(2
σ
, standard deviation)
- to laser beam
- to the housing
± 0.3°
± 0.3°
Indirect measurement
using tilt sensor (direct
horizontal distance)
9
Angle measurement using
tilt sensor(
± 45°)
9
Page view 39