Makita G12010R Owner's Manual

Browse online or download Owner's Manual for Power generators Makita G12010R. Makita G12010R Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ISSUE EMD-GU2000
PRINTED IN JAPAN
October 2004 CE-SK 100
Makita Corporation
3-11-8, Sumiyoshi-cho
Anjo, Aichi 446-8502 Japan
3ZZ9020161
GENERATOR
INSTRUCTIONS FOR USE
アメリカ
ISSUE EMD-GU1539
PRINTED IN JAPAN
Makita Corporation
3-11-8, Sumiyoshi-cho
Anjo, Aichi 446-8502 Japan
3ZZ9020107
GENERATOR
INSTRUCTIONS FOR USE
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - GENERATOR

ISSUE EMD-GU2000PRINTED IN JAPANOctober 2004 CE-SK 100Makita Corporation3-11-8, Sumiyoshi-choAnjo, Aichi 446-8502 Japan3ZZ9020161GENERATORINSTRUCTIONS

Page 2 - AIR INDEX

Check that followingaccessories come with yourMakita Generator.(1) Instruction for use(2) Servicing tools(3) Battery mounting bracket (See page 8 and

Page 3

CONTENTS1. SAFETY PRECAUTIONS・・・・・・・・・・・・・・・・・・・・・・12. SPECIFICATIONS・・・・・・・・・・・・・・・・・・・・・・・・・・43. COMPONENTS・・・・・・・・・・・・・・・・・・・・・・・・・・・54. PRE-OPERAT

Page 4

−1−1. SAFETY PRECAUTIONSDo not operate the generator near gasoline or gaseous fuel because of thepotential danger of explosion or fire.Do not fill the

Page 5

−2−Operate the generator on a level surface.It is not necessary to prepare a special foundation for the generator. However,the generator will vibrate

Page 6

−3−Engine becomes extremely hot during and for some time after operation.Keep combustible materials well away from generator area.Be very careful not

Page 7

2. SPECIFICATIONS−4−Model G12010RAlternatorType Brush, Self-exciting, 2-pole, Single-phaseRated voltage 120V / 240V9500 VAA.V.R typeEngineModel EH65DT

Page 8

3. COMPONENTS−5−SPARK PLUG CAPFUEL COCKBATTERYTANK CAPSPARK PLUGCAPOIL FILLER CAPMUFFLEROIL GAUGECONNECTORFOR REMOTECONTROLELECTRIC STARTEROIL DRAIN P

Page 9 - FOREWORD

−6−UPPERLEVELLOWERLEVELOIL GAUGEOil gaugeUpper levelLower level4. PRE-OPERATION CHECKCHECK ENGINE OILBefore checking or refilling oil, be suregenerato

Page 10 - (See page 8 and 9.)

1) Check fuel level at fuel level gauge.2) If fuel level is low, refill with automotiveunleaded gasoline only.This engine is certified to operate onau

Page 11 - CONTENTS

−8−Make sure you review each warning in order to prevent fire hazard. Do not refill tank while engine is running or hot. Close fuel cock before refuel

Page 12 - 1. SAFETY PRECAUTIONS

The engine exhaust from this product containschemicals known to the State of California tocause cancer, birth defects or other reproductiveharm.WARNIN

Page 13

−9−RED CABELRED CABELLESS THAN10.2 in. (260 mm)LESS THAN6.7 in. (170 mm)LESS THAN8.1 in. (205 mm)① Butterfly nut┓ ② Long bolt┣ Accessory③ Supporting

Page 14 - Notes on installation

CHECK COMPONENT PARTSCheck following items before starting engine: Fuel leakage from fuel hose, etc. Bolts and nuts for looseness. Components for dama

Page 15 - 2. SPECIFICATIONS

(1) Make sure that the no-fuse breaker isoff.(2) Turn the fuel cock to the vertical(open) position(3) Turn the key switch to the "START"posi

Page 16 - 3. COMPONENTS

−12−USING ELECTRIC POWER Make sure that the appliance is switched OFF before connecting it tothe generator. Do not move the generator while it is runn

Page 17 - 4. PRE-OPERATION CHECK

−13−(1) AC APPLICATION(a) Ground the generator, using theground terminal located at the side ofthe panel.(b) Before starting the engine, check thatthe

Page 18 - CHECK ENGINE FUEL

−14−up to 30Aup to 30Aup to 20ANEMA5-20RNEMAL5-30RNEMAL14-30RNEMA5-20PNEMAL5-30PNEMAL14-30PGFCI (Ground FaultCircuit Interrupter)Receptacle, duplex(RE

Page 19 - BATTERY INSTALLATION

−15−The duplex 120V receptacle is protected by a GFCI (Ground Fault CircuitInterrupter). GFCI shuts off the output current from the duplex 120Vrecepta

Page 20 - [CAUTION]

−16−MAIN POWER LINETRANSFER SWITCHUTILITY HIGH LINECONNECTING BOX240VRECEPTACLE(a) When connecting a Makita generator to a house wiring, generator out

Page 21 - CHECK GENERATOR SURROUNDINGS

−17−Utility high lineMeter boxGeneratorHouse circuit breakerXWYX(X)(Y)(G)(W)WYXWYTransferswitch240V4P- Receptacle120Vappliance120Vappliance240Vapplian

Page 22 - 5. OPERATING PROCEDURES

−18−(e) Turn on the switch of the appliance.PILOT LAMPNOTE :When the no-fuse breaker turns off duringoperation, the generator is over loaded orthe app

Page 23 - USING ELECTRIC POWER

FEDERAL EMISSIONS COMPONENT DEFECT WARRANTYEMISSIONS COMPONENT DEFECT WARRANTY COVERAGE - This emission warranty isapplicable in all States, except th

Page 24 - Grounding spike

−19−(3) IDLE CONTROL SWITCHIDLECONTROL SWITCHautomatically reduces engine speed when load is OFF,and automatically increases engine speed to rated r.p

Page 25 - Receptacle, duplex

−20−CLOSECLOSEOPEN(6) Close the fuel cock.STOPPING THE GENERATOR(1) Turn off the power switch of theelectric equipment.(2) Turn the no-fuse breaker t

Page 26

6. WATTAGE INFORMATION−21−Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to s

Page 27

−22−To determine the total wattage required to run a particular electrical appliance ortool, multiply the voltage figure of the appliance/tool by the

Page 28

7. SPARK ARRESTER−23−SPARK ARRESTERIn a dry or wooded area, it is recommendable to use the product with a spark arrester.Some areas require the use of

Page 29 - PILOT LAMP

8. MAINTENANCE SCHEDULE−24−DAILY INSPECTIONBefore running the generator, check the following service items:Excessive vibration,noiseClean air cleaner

Page 30

−25−(Periodic Maintenance Schedule table)*Note 1 : Initial oil change should be performed after first twenty (20) hours of operation.Thereafter change

Page 31 - STOPPING THE GENERATOR

9. "HOW-TO" MAINTENANCE−26−OIL FILTERENGINE OIL CHANGE Initial oil change・・・・・After 20 hours of operation Thereafter・・・・・Every 100 hours o

Page 32 - 6. WATTAGE INFORMATION

−27− Urethane Foam cleaning Wash and clean the urethane foam inkerosene. Saturate in a mixture of 3parts kerosene and 1 part engine oil, andthen sque

Page 33 - Resistance

−28−Spark plugNGK BPR5ES (CHAMPION RN11YC)CLEANING FUEL STRAINERDirt and water in the fuel are removed bythe fuel strainer.(a) Remove the strainer cup

Page 34 - 7. SPARK ARRESTER

*The replacement parts used for required maintenance services.*Consequential damages such as loss of time, inconvenience, loss of use of the engineore

Page 35 - 8. MAINTENANCE SCHEDULE

−29−CHECKING CARBON BRUSH If the brush become excessively worn, itscontact pressure with the slip ringchanges and causes a roughened surfaceon the sli

Page 36 - (Every 100 hours)

10. PREPARATION FOR STORAGE−30−The following procedures should be followed prior to storage of your generator fora period of 6 months or longer. Drain

Page 37 - REPLACEMENT

11. TROUBLESHOOTING−31−When generator engine fails to start after several attempts, or if no electricity isavailable at the output receptacles, check

Page 38 - SPARK PLUG

12. WIRING DIAGRAM−32−Blk/Y5324(AC output)(AVR)1CONTROL BOXFuel cutIgnition coilAuto choke(Bimetal)ElectricstarterOil pressureswitchRegulatorMagnetics

Page 39 - FUEL HOSE REPLACEMENT

ISSUE EMD-GU2000PRINTED IN JAPANOctober 2004 CE-SK 100Makita Corporation3-11-8, Sumiyoshi-choAnjo, Aichi 446-8502 Japan3ZZ9020161GENERATORINSTRUCTIONS

Page 40 - CHECKING CARBON BRUSH

CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT(This warranty does not apply in any other state.)YOUR WARRANTY RIGHTS AND OBLIGATIONSThe California Air

Page 41 - 10. PREPARATION FOR STORAGE

MAKITA , a distributor of small off-road equipment in the U.S., warrants to the owner of 2005and later engines that the engine (1) has been designed,

Page 42 - 11. TROUBLESHOOTING

WHAT IS NOT COVERED UNDER THIS WARRANTYThis warranty does not cover any emission-related part which malfunctions, fails, or isdamaged due to alteratio

Page 43 - 12. WIRING DIAGRAM

REPAIR AND REPLACEMENT OF EMISSION-RELATED PARTSIt is recommended that only engine replacement parts which have been authorized andapproved by MAKITA

Page 44

Thank you for purchasing a Makita generator.This manual covers operation and maintenance of the Makita generators.All information in this publication